1. MODIFICATION OF HEIGHT LIMITATIONS. The district height limitations stipulated elsewhere in this Chapter may be exceeded, but such modification shall be in accord with the following:#
a. ARCHITECTURAL PROJECTIONS, such as spires, belfries, parapet walls, cupolas, domes, flues and chimneys, are exempt from the height limitations of this Chapter.#
b. SPECIAL STRUCTURES, such as elevator penthouses, gas tanks, scenery lofts, radio and television receiving antennas, manufacturing equipment and necessary mechanical appurtenances, cooling towers, fire towers, substations and smokestacks, are exempt from the height limitations of this Chapter.#
c. ESSENTIAL SERVICES, utilities, water towers, electric power and communication transmission lines are exempt from the height limitations of this Chapter.#
d. COMMUNICATION STRUCTURE, such as radio and television transmission and relay towers, aerials, and observation towers, shall not exceed in height three (3) times their distance from the nearest lot line.#
e. PUBLIC OR SEMI-PUBLIC FACILITIES, such as schools, churches, hospitals, monuments, sanitariums, libraries, governmental offices and stations, may be erected to a height of sixty (60) feet, provided all required yards are increased not less than one (1) foot for each foot the structure exceeds the district’s maximum height requirement.#
f. Penthouses, stage towers, scenery lifts, elevators, bulkheads, clock towers, cupolas, water tanks, and similar structures and mechanical appurtenances may be erected on a building to a height greater than the limit for the district in which the building is located, provided that no such exception shall cover, at any level, more than twenty-five (25%) percent of the area of the roof on which it is located: provided, further, that no such exception shall be used for sleeping or housekeeping purposes or for any commercial purpose other than such as may be incidental to the permitted use of the main building.#
2. LOT WIDTH AND AREA.#
a. Requirements as to lot width and area for the construction of a one- and two- family dwelling shall not apply to any lot having less than the required area or width at the time of adoption of this Chapter or any amendment thereof increasing the area of width required for such lot, and held at the time in separate ownership from that of adjoining land, provided that the area and the width of such existing lot shall be no less than seventy-five (75%) percent of the required minimum set forth in this Chapter.#
b. In situations where a vacant lot is not held in separate ownership but is adjacent to an existing developed home site, the vacant parcel may only be developed if it meets the above seventy-five (75%) percent minimum lot width and area criteria and if the remaining lot area of the developed lot also meets these same standards.#
3. BUILDING SETBACKS. In Residential Districts, except for corner lot, required setbacks may be modified where sixty (60%) percent or more of the frontage on a block is occupied by residences having setbacks less than that required by this Chapter, setback on each remaining lot shall be determined in accordance with the following rule. The front building line of a proposed structure shall be no nearer the front lot line than a line joining adjacent front corners of the nearest principal structures, which are in the same block frontage on either side of the proposed structure. If, on a block frontage, no principal structure exists to one side of a proposed structure, a structure may be assumed to exist on the corner lot which conforms to the minimum setback and side yard width requirements of this Chapter.#
4. EXTENSIONS OF STRUCTURES INTO REQUIRED YARDS.#
a. The following extensions shall be permitted into required yards:#
1. Canopies and marquees in Business Districts, 6 feet (not permitted in interior side yards)#
2. Cornices and similar extensions, 1 foot#
3. Open fireproof fire escapes, 3 feet#
4. Eaves, 2 feet#
5. Front Yard Porches and Decks, 5 feet on existing residences only,#
b. The following restrictions shall apply to the permitted extensions:#
1. Cornices, canopies, marquees and similar extensions shall be at least ten (10) feet above ground level.#
2. Canopies shall, in no case, extends nearer than three (3) feet back of the face of a curb.#
c. Located within Residential Zoning District subject to the following conditions and restriction:#
1. The residence shall be in existence prior to the effective date of this ordinance.#
2. The porch or deck shall be allowed a maximum of a 5-foot encroachment into the required 30-foot setback from the front property line.#
3. The porch or deck shall consist of an open design and shall not have any windows or doors or a screened enclosure. Open spindle and railing designs shall be allowed to a maximum of 4 feet above the level of the porch or deck floor.#
4. A roof structure over the porch or deck is allowed but shall not extend or overhang the floor of the porch or deck more than 2 feet and no part of the structure supports of the roof shall extend more than 5 feet into the required front yard setback, the same as the floor encroachment allowed for the porch or deck.#
A reading copy of the adopted code, from page 27 to 28 of the official chapter PDF. The PDF is the legal text.