1. Work Authorized. No unauthorized person shall uncover, make any connections with or opening into, use, alter, or disturb any public sewer or appurtenance thereof, without first obtaining a written permit from the Approving Authority.#
2. Cost of Sewer Connection. All costs and expense incident to the installation and connection of the building sewer shall be borne by the owner.#
3. Use of Old Building Sewers. Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the Approving Authority, to meet all requirements of this ordinance.#
4. Materials and Methods of Construction. The size, slope, alignment, materials of construction of a building sewer, and the methods to be used in excavating, placing of the pipe, jointing, testing and backfilling the trench, shall all conform to the requirements of the building and plumbing code or other applicable rules and regulations of the municipality. In the absence of code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the Department of Safety and Professional Services SPS 381 through 387 shall apply.#
5. Building Sewer Grade. Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such building drain shall be lifted by an approved means and discharged to the building sewer.#
6. Storm and Ground Water Drains. No person shall make connection of roof downspouts, exterior foundation drains, areaway drains, or other sources of surface runoff or ground water to a building sewer or building drain which is connected directly or indirectly to a public sanitary sewer.#
7. Conformance to Plumbing Codes. The connection of the building sewer into the public sewer shall conform to the requirements of the building and plumbing code or other applicable rules and regulations of the Department of Safety and Professional Services SPS 381 through 387 and Section 27.09 of this Code. All such connections shall be made gas tight and watertight. Any deviation from the prescribed procedures and materials must be approved by the Approving Authority before installation.#
8. Inspection of Connection. The applicant for the building sewer permit shall notify the Approving Authority when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Approving Authority.#
9. Barricades: Restoration. All excavations for the building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the municipality.#
A reading copy of the adopted code, from page 8 of the official chapter PDF. The PDF is the legal text.